Product

DC Breakdown Voltage (V)

Tolerance

First Breakdown Voltage (V)

Insulation min. (ohm)

Capacictance (pF)

Temperature range (Celsius)

Minimum number of switchings

Ordering code

8296

1000

±15%

-

>1E8

1

-40 to 160

200 000

ST 1000 ACX SG

8296/1

1000

±15%

<1200

>1E8

1

-40 to 160

200 000

ST 1000 ALX SG

8289/1

840

756V...941V

<1100

>1E8

1

-40 to 160

200 000

ST 0840 BLX OB

8298/1

840

740V...940V

<950

>1E8

1

-40 to 160

200 000

ST 0840 BLX STD

8291

800

±15%

<1000

>1E8

1

-40 to 160

200 000

ST 0800 ACX STD

8291/1

800

±15%

<950

>1E8

1

-40 to 160

200 000

ST 0800 ALX STD

8297

800

±12%

<950

>1E8

1

-40 to 160

200 000

ST 0800 BCX STD

8297/1

800

±12%

<950

>1E8

1

-40 to 160

200 000

ST 0800 BLX STD

8299

800

±12%

-

>1E8

1

-40 to 160

200 000

ST 0800 BCX SG

8299/1

800

±12%

<950

>1E8

1

-40 to 160

200 000

ST 0800 BLX SG

8298

800

-7% +17%

-

>1E8

1

-40 to 160

200 000

ST 0800 BCX B

8287/1

800

-10% +12%

<1000

>1E8

1

-40 to 160

200 000

ST 0800 BLX OB

8311/1

800

±12%

<950

>1E8

1

-40 to 160

200 000

ST 0800 BLX Z

8288/1

620

±12%

<750

>1E8

1

-40 to 160

200 000

ST 0620 BLX STD

8309/1

620

560V...680V

<750

>1E8

1

-40 to 160

200 000

ST 0620 BLX H

8293

600

±15%

-

>1E8

1

-40 to 160

200 000

ST 0600 ACX SG

8293/1

600

±15%

-

>1E8

1

-40 to 160

200 000

ST 0600 ALX SG

8292

600

±12%

-

>1E8

1

-40 to 160

200 000

ST 0600 BCX SG

8292/1

600

±12%

<750

>1E8

1

-40 to 160

200 000

ST 0600 BLX SG

8308/1

600

±12%

<750

>1E8

1

-40 to 160

200 000

ST 0600 BLX STD

10208/1

470

±12%

< 620

>1E8

1

-40 to 160

200 000

ST 0470 BLX STD

8294

400

±15%

-

>1E8

1

-40 to 160

200 000

ST 0400 ACX SG

8294/1

400

±15%

<500

>1E8

1

-40 to 160

200 000

ST 0400 ALX SG

8301

400

±12%

-

>1E8

1

-40 to 160

200 000

ST 0400 BCX SG

8301/1

400

±12%

<500

>1E8

1

-40 to 160

200 000

ST 0400 BLX SG

10204/1

400

±12%

<500

>1E8

1

-40 to 160

200 000

ST 0400 BLX STD

 


2 Electrode Gas Discharge Tube

Product

DC Breakdown Voltage (V)

Holdover Voltage (V)

Dynamic Breakdown Voltage (V)

Insulation min. (ohm)

Capacictance (pF)

Impulse Discharge current/ applications

Nominal AC discharge current/ applications

Comments

8270
8270/1

470

-

<1200

>1E9

2

5kA/10
100A/500

5A/5

Telecom
Surge Arrester

8263
8263/1

350

150

<1000

>1E9

2

20kA/10
100A/500

5A/10

Telecom
Surge Arrester

8264
8264/1
8264/2

350

150

<1000

>1E10

2

10kA/5
1kA/50
100A/50

20A/20

Telecom
Surge Arrester

8269
9269/1

350

-

<1000

>1E9

2

5kA/10
100A/500

5A/5

Telecom
Surge Arrester

8265
8265/1

230

150

<900

>1E9

2

5kA/10
100A/500

5A/5

Telecom
Surge Arrester

á TOP

 


2 Electrode other

Product

DC Breakdown Voltage (V)

Holdover Voltage (V)

Dynamic Breakdown Voltage (V)

Insulation min. (ohm)

Capacictance (pF)

Impulse Discharge current/ applications

Nominal AC discharge current/ applications

Comments

8266
6200
6200 - <8000 >1E10 1 5kA/10 - High Voltage
Surge Arrester
8266
5500
5500 - <8000 >1E10 1 5kA/10 - High Voltage
Surge Arrester
8266
5500B
5500 - <8000 >1E10 1 5kA/10 - High Voltage
Surge Arrester
8266
3000
3000 - <6000 >1E10 1 5kA/10 - High Voltage
Surge Arrester
8266
3000B
3000 - <6000 >1E10 1 5kA/10 - High Voltage
Surge Arrester

á TOP

 


3 Electrode Gas Discharge Tube

Product

DC Breakdown Voltage (V)

Holdover Voltage (V)

Dynamic Breakdown Voltage (V)

Insulation min. (ohm)

Capacictance (pF)

Impulse Discharge current/ applications

Nominal AC discharge current/ applications

Comments

8273/1 350 150 <1000 >1E9 2 5kA/10 5A/5 Telecom
Surge Arrester
8274/1 350 150 <1000 >1E10 2 10kA/5
1kA/50
100A/50
20A/20 Telecom
Surge Arrester
8275/1 230 150 <900 >1E9 2 5kA/10
100A/500
5A/5 Telecom
Surge Arrester

á TOP

  • All our products are nonradioactive and toxic free.